Accommodative facility in myopes and non-myopes at Mechi Netra 9Eye Hospital) at Japa district, Eastern Nepal (Record no. 3449)

MARC details
000 -LEADER
fixed length control field 02396nam a22001697a 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250214125458.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 250214b |||||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Description conventions Local
060 ## - NATIONAL LIBRARY OF MEDICINE CALL NUMBER
Classification number RES01207
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Mechi Netralaya and Ophthalmic Research Center
245 ## - TITLE STATEMENT
Title Accommodative facility in myopes and non-myopes at Mechi Netra 9Eye Hospital) at Japa district, Eastern Nepal
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Jhapa;
Name of publisher, distributor, etc. Mechi Netralaya and Ophthalmic Research Center;
Date of publication, distribution, etc. a2019
300 ## - PHYSICAL DESCRIPTION
Extent 25p.
520 ## - SUMMARY, ETC.
Summary, etc. Objective: <br/>Many studies have shown that the myopes have abnormal accommodative characteristics. This study aimed at measuring the accommodative facility of myopes and non-myopes and compare between them. <br/>Method: <br/>Distance and near accommodative facility in cycles per minute(cpm) were measured using ±2 D flippers. 100 patients (50 myopes and 50 non-myopes) aged between 15-25 years were taken as the research participants visited in OPD of Mechi Netralaya and Ophthalmic Research Centre, of Mechinagar-6, Jhapa. Only the right eye data was considered for the analysis. Difference between the groups were analyzed with the ANOVA (Brown-Forsythe F Test). <br/>Findings: <br/>This Mean distance facility was significantly lower (5.3 ± 2.8 cpm) in the myopic group compared with the mean distance facility in the non-myopic group (8.7 ± 3.1 cpm). Mean near facility was also significantly lower (4.3 ± 1.8 cpm) in the myopic group compared with the mean near facility in the non-myopic group (6.6 ± 2.4 cpm). But, both distance and near Accommodative facility was not significantly different among the age groups. The area under the receiver operating characteristics (ROC curve) for distance facility was 0.784 (P <0.001, 95% CI, 0.696–0.87), suggesting that distance cpm had only a fair ability to discriminate between myopic and non-myopic eyes. Hence, the accommodative facility cannot be used as a stand-alone discriminatory test to predict myopia. <br/>Conclusions: <br/>There was no any difference in the accommodative facility between age group. Myopic eyes have reduced accommodation facility at both distance and near. However, accommodative facility as a test does not have sufficient power to distinguish eyes with myopes and non-myopes of age between 15-25 years.<br/>
856 ## - ELECTRONIC LOCATION AND ACCESS
Link text https://elibrary.nhrc.gov.np/handle/20.500.14356/2672
Public note Click over the link for Full text.
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme National Library of Medicine
Koha item type Research Report
Suppress in OPAC Yes
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Source of acquisition Inventory number Total Checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type Public note
    National Library of Medicine     Nepal Health Research Council Nepal Health Research Council General Stacks 02/14/2025 Provincial Grant 01207   RES01207/MNO/2019 RES01207 02/14/2025 1 02/14/2025 Research Report Provincial Research Report.

Nepal Health Research Council © 2024.

Ramshah Path, Kathmandu, Nepal, P.O.Box 7626

Web: https://nhrc.gov.np/ | Email : nhrc@nhrc.gov.np | Phone : 977-1-4254220

Maintained by Chandra Bhushan Yadav, Library & Information Officer, NHRC